| Model | ULB-T26 |
| Standards | GB/T 11048, ISO 11092, ASTM F 1868-09, ASTM D 1518-85, JIS L1096-2010, ASTM F 1868-02 |
| Thermal Resistance (RCT) Range | 0.002-2.0 m2.K/W |
| Indication Error | ≤±2% |
| Repeatability Error | ≤ ± 2% |
| Resolution | 0.0001 m2.K / W |
| Dampness (Ret) Range | 0 ~ 1000 m2.Pa/W |
| Test Plate Temperature Range | 30 ℃ -40 ℃ Adjustable |
| Temperature Control Accuracy | ± 0.03 ℃ |
| Temperature Resolution | ± 0.01 ℃ |
| Power Supply | 1∮ AC 220V 50/60Hz |
| Speed Control Accuracy | ± 1% |
| Sample Platform Lift Range | 0-70mm Automatic Lifting |
| Specimen Thickness | 0-70mm |
| Test Pleat Size | 250mm×250mm |
| Size for Specimen | 512mm×512mm |
| Width for Heating Protection Ring | 127mm |
| Outside Chamber Dimension | 1700x1350x1890mm(L×W×H) |
| Outside Chamber Weight | 250Kg |
| Power | 3 ∮AC380V±10%, 50/60Hz, 10KW |
Accessories
| Standard accessories | 1pc | English Operation Software |
| 1pc | Temperature and Humidity Chamber | |
| 1pc | Power line |
Q1: What is the main application of the Sweating Guarded Hot Plate?
It is designed to determine the thermal and evaporative resistance of clothing materials by heating a fixed aluminum or copper plate to maintain a fixed temperature and heating power, and testing the power difference once covered with the test fabric.
Q2: Which testing standards does the ULB-T26 model comply with?
The device complies with various major standards including GB/T 11048, ISO 11092, ASTM F 1868-09, ASTM D 1518-85, JIS L1096-2010, and ASTM F 1868-02.
Q3: What is the measurable range for Thermal Resistance (RCT) and Dampness (Ret)?
The Thermal Resistance (RCT) range is 0.002 to 2.0 m².K/W, and the Dampness (Ret) range is 0 to 1000 m².Pa/W.
Q4: How does the platform adjust for different specimen thicknesses?
The system features a high-precision automatic platform moving system with an automatic lifting range of 0-70mm. Users can input the specimen thickness, and the platform automatically moves to the corresponding position.
Q5: What are the standard accessories included with the ULB-T26?
It comes standard with 1pc English Operation Software, 1pc Temperature and Humidity Chamber, and 1pc Power line.
Q6: What is the temperature control accuracy of the test plate?
The test plate has an adjustable temperature range of 30 ℃ to 40 ℃ with a high control accuracy of ± 0.03 ℃ and a temperature resolution of ± 0.01 ℃.