Automatic Air Permeability Test Equipment ULB-T06B
Application
This Air Permeability Test Equipment is used to measure the air permeability of a variety of textile fabrics, including industrial fabrics, non-woven fabrics and other textile products and other air-permeable materials.
Standards
GB/T 5453, GB/T 13764, ISO 9237, ISO 7231, ISO 5636, BS 5636, ASTM D737, DIN 53887, JISL1096, AFNORG 07-111, EDANA140.1
Features
1. 7-Inch Touch Screen Control as well as operating by connect to the computer.
2. Full range and automatic detection.
3. Test head size can be automatically sense, and replacement is simple and convenient.
4. Adopt USA SMI high-precision pressure and differential pressure transducer to accurate data.
5. Variable hole test plate can be automatically cleaned to ensure accuracy.
6. Air Permeability Tester equipped with thermal printer to print the experiment result.
7. Microcomputer processing without manual calculation and the test result can displayed directly.
8. Built-in 7 testing units: mm/s, m3/m2.min, cm3/cm2.s, m3/m2.h, cfm, L/dm2.min, L/m2.s
9.Testing arm is pneumatic controlled and can press and put up automatically.
10. Air Permeability Tester equipped with 11 nozzle with different calibers to meet different specimens.
2. Full range and automatic detection.
3. Test head size can be automatically sense, and replacement is simple and convenient.
4. Adopt USA SMI high-precision pressure and differential pressure transducer to accurate data.
5. Variable hole test plate can be automatically cleaned to ensure accuracy.
6. Air Permeability Tester equipped with thermal printer to print the experiment result.
7. Microcomputer processing without manual calculation and the test result can displayed directly.
8. Built-in 7 testing units: mm/s, m3/m2.min, cm3/cm2.s, m3/m2.h, cfm, L/dm2.min, L/m2.s
9.Testing arm is pneumatic controlled and can press and put up automatically.
10. Air Permeability Tester equipped with 11 nozzle with different calibers to meet different specimens.
Key Specification
|
Model |
ULB-T06B |
|||||||||||
|
Operation display |
Touch Screen |
|||||||||||
|
Nozzle Changing method |
Automatically |
|||||||||||
|
Test time |
10~15s |
|||||||||||
|
Nozzle pressure difference |
4,000Pa |
|||||||||||
|
Specimen pressure difference |
1,000Pa |
|||||||||||
|
Data port |
RS232C |
|||||||||||
|
Permeability range |
0.1~12000mm/s |
|||||||||||
|
Measuring error |
≤±2% |
|||||||||||
|
Measuring unit |
mm/s, m3/m2/min, cm3/cm2/s, m3m2/h, L/dm2/min, L/m2/s, cfm |
|||||||||||
|
Testing area |
5cm2, 20cm2, 50cm2, 100cm2 , Ф50mm (≈19.6cm2), Ф70mm(≈38.3cm2) |
|||||||||||
|
Fabric thickness |
≤12mm |
|||||||||||
|
Nozzle parameter |
Number |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
|
|
Dia. mm |
0.8 |
1.2 |
2 |
3 |
4 |
6 |
8 |
10 |
12 |
16 |
||
|
Power supply |
AC 220V 50/60HZ, 2KW |
|||||||||||
|
Dimensions |
1020 x 460 x 1016mm (L x W x H) |
|||||||||||
|
Weight |
93kg |
|||||||||||